School Science Lessons
2023-12-31
Please send comments to: johnelfick@hotmail.com
(Electricalhazards.html) Acknowledgement

Electrical hazards
Table of contents
4.2.11 Australian voltage
1.0 Electrical fires
2.0 Electrical outlets and equipment

4.0 Electrical hazards, Electric shock
4.1.1 Effects of electric current passing through the human body
4.1.2 "Let-go" current
4.1.3 Causes of electric current passing through the human body
6.3.1.4 Electric shock, Ampere

4.2.0 Safe practices and procedures
3.6.2 Electrical safety rules
4.2.1 Power points and switches
4.2.2 Mains-operated equipment
4.2.3 Electrical leads
4.2.4 Electrical inspections tests
4.2.5 Reporting an accident
4.2.6 Isolating transformers [deleted]
4.2.7 Precautions to take when using an isolating transformer [deleted]
4.2.8 Core balance earth leakage devices
4.2.9 Precautions to take when using core balance earth leakage devices
4.2.10 Management of electric shock victims

1.0 Electrical fires
1. The electrical wiring in science laboratories, and other activity areas should be adequately protected against overloading by circuit breakers.
Repairs should be done only by a qualified electrician.
2. Wiring should not be overloaded by using appliances, or equipment whose current rating is greater than that of the power outlet.
General purpose outlets (GPOs) were usually rated at 10 amps.
Some GPOs may be rated at 15 amps.
3. The use of double adapters should be avoided.
Portable power boards (multiple point power boards), especially those with circuit breakers, should be used.
4. All power leads must be in good condition, of the appropriate current rating for the appliance(s) being used, and of the minimum length necessary for practical use.

2.0 Electrical outlets and equipment
Electrical outlets
1. Permanent general purpose electrical outlets must be in a safe and operational condition.
2. New installations must be fitted with automatic blind outlets.
For further information regarding electrical safety refer to Section Commercial electrical equipment
3. The Regulatory Unit of the Department of Minerals and Energy (DME), the Queensland Electricity Industry [QEI] has set down stringent guidelines for equipment operating on 240 volts.
4. Teachers are reminded that home-made 240V equipment would be unlikely to comply with legal specifications.
5. All 240V electrical equipment should be serviced and checked by a qualified electrician.
 6. Equipment suppliers must supply schools with equipment that complies with QEI specifications, including appropriate earthing and use of approved insulating materials.

4.1.1 Effects of electric current passing through the human body
1. Breathing can stop
2. The heart can stop
3. Burns to the skin and internal organs
4. Muscle spasm
5. Clinical shock (a reaction of the body's nervous system to severe injury)
6. Falls may cause injuries
The danger to persons caused by an electric current passing through the human body depends upon the value of the current.
However, it is difficult to calculate what this current will be under any given set of circumstances.
The relationship of current to voltage is not linear, because body resistance varies with the touch voltage and with the path taken by the current.

4.1.2 "Let-go" current (sometimes called the "cannot let-go" current)
This is defined as the maximum current a person can tolerate when holding an electrode, and still let go of this electrode using muscles directly stimulated by this current.
Experimental evidence places the value of this current at about 10 milliamperes.
Higher currents would cause muscle freezing, preventing persons from releasing their hand from the conductor.

4.1.3 Causes of electric current passing through the human body
An electric shock could be received from the following:
1. Wall or bench outlets (power points),
2. Switches,
3. Mains-operated equipment,
4. Leads connecting equipment to power points,
5. Extension leads.
In Queensland, the electricity reticulation system is MEN (Multiple Earth Neutral), i.e. the neutral wire is earthed at the powerhouse, at the point of
supply to each consumer and at other points along the line between powerhouse and consumer.
If a person comes into contact with a live conductor connected to the mains, e.g. the active pin in a power point or switch or an exposed active wire
in a lead, for a touch voltage of 240 volts AC, the body resistance between its extremities is of the order of 1000 ohms.
Under these conditions, the current flowing through the person would be 240 milliamperes, mA.
This current could produce serious results.
If the earth lead is faulty or broken, i.e. high resistance, the greater part of the earth leakage current will flow through the person.
The fuse will not blow, because the current is insufficiently high and the effect on the person could be fatal.

4.2.1 Power points and switches
1. Dry hands thoroughly before operating any switch.
2. Do not allow the cover plates of power points or switches to be removed.
If, for any reason, the cover plate has been removed or damaged, do not allow the point or switch to be used until it has been repaired by a qualified electrician.
3. Switches must be in the "off" position before inserting plugs or removing plugs from power points.
4. Grasp the plug, not the lead, when removing plugs from power points.
Hold the plug firmly and pull away.
5. Do not allow students to tamper with power points or switches, e.g. by pushing metal objects into power points or poking at pilot lights with metal objects.
6. If a power point or switch is faulty in any way, do not attempt to repair it yourself.
Do not allow students to use it until it is repaired.
7. Cover power points with plug protectors when not in use.
8. Hand-held equipment (e.g. electric drills), unless double insulated, must be operated through an isolating transformer or a core balance earth leakage device.
These are designed to protect the operator from injury from faulty earth connections.

4.2.2 Mains-operated equipment
See: Mains lead (Commercial)
Mains operated equipment has to meet the stringent requirements laid down by the Queensland Electricity Industry (QEI), e.g. that it be effectively
earthed, (unless double insulated), and that the lead from the equipment to the power point be effectively anchored within the equipment, so that it
cannot be pulled loose.
1. If the equipment installed by the Department of Public Works and Housing, e.g. hot water systems, stills, fans, refrigerators, reticulated DC supplies
fails to function, teachers should not attempt to repair it.
This is not only dangerous, but illegal.
Faults should be reported to the nearest depot of the Department of Public Works and Housing or the principal may arrange for a local electrician to effect repairs.
2. Avoid using 240 volt equipment near sinks or water outlets or close to gas outlets where accidental sparking may ignite gas leaks.
3. Disconnect portable appliances from the power outlet when not in use.
4. Before attempting to clean any mains operated equipment (portable or fixed), ensure that it is switched off and disconnected from the power point.
5. Hand held equipment, e.g. electric drills, unless double insulated,   must be operated through an isolating transformer, or a core balance earth  leakage device.
These are designed to protect the operator from injury in the event of faulty earth connections.

4.2.3 Electrical leads
Most mains operated equipment is connected to power points through leads that contain three wires.
They are colour coded as follows:
Table 4.2.3   
Lead Current Australian standard International standard
Live Red Brown
Neutral Black Blue
Earth Green Green / Yellow
Both these standards are presently acceptable to the Queensland Electricity Industry.
The earth lead (green or green/yellow), is meant to earth the frame, or metal case of the equipment, to prevent shock to the user, should a short circuit
occur between the electrically "live" parts of the equipment and the frame or case.
The other two wires in the lead (red and black or brown and blue), carry the electric current operating the equipment.
The following safe practices should be followed:
1. Inspect all leads and fittings regularly for frayed or cracked insulation.
If a lead is considered defective, it should be  checked by a qualified electrician.
2. Never use a lead if the plug that fits into the mains operated equipment, or the three pin plug that fits into the power point are damaged or loose.
3. Never twist or knot a lead or bend it sharply.
4. Never tack leads to walls.
5. Store leads when not in use in such a way that the insulation will not be damaged.
6. Avoid using extension leads, where possible.
If necessary, use commercially available leads.
Home-made leads must not be used.
7. Always switch off the equipment before attempting to disconnect extension leads.
8. Use the shortest possible continuous lead.
9. Use a power board when several appliances need to be plugged in.
Do NOT use double adapters!

4.2.4 Electrical inspections tests
Checks are usually arranged through the principal.
All movable electrical equipment that has a lead fitted, or that requires a lead to be attached, and all extension leads, are to be checked at prescribed
intervals and tagged by a qualified electrical worker, in accordance with Australian Standard AS 3760-1990 "In-service inspection and testing of
electrical equipment".
It should be noted that damage may be caused to specialized electronic equipment, e.g. as photocopiers, computers, typewriters and facsimile machines
if they are not tested correctly.
The following table outlines the testing requirements:
Table 4.2.4
Environment where equipment is used Intervals between inspection and test Intervals between inspection and test Intervals between inspection and test Intervals between inspection and test
-
Class of equipment Class of equipment Additional tests for portable safety switches Additional tests for portable safety switches
-
Class I (Earthed) TV, Stereo
 Class II (double Insulated) hair dryer, electric drill, shaver
Interval for push-button test by user Interval for performance test
Manual arts, cleaning room, home economics, tuck shop, agriculture,
science
 
6 months 12 months Daily 12 months
Science Department
staff rooms
12 months 12 months Daily 5 years
Records are required for all items of electrical equipment, including the dates of each test, and the name and licence number of the qualified electrical
worker, to be kept and to be made readily available to a Division of Accident Prevention inspector upon request.

4.2.5 Reporting an accident
Any accident involving mains power should be reported to the local electrical authority, which will conduct an investigation and report to the QEI.
Such action may prevent further accidents from similar causes.

4.2.8 Core balance earth leakage devices
Core balance earth leakage devices work on the principle of current balance.
In any electrical equipment, which are in good condition, the currents in the active and neutral conductors are equal and opposite.
A current transformer placed around these two conductors will have no secondary voltage induced or current flowing.
If the equipment is earthed and the insulation resistance between equipment and the earth is low, some of the load current will flow to earth instead of
returning through the neutral (earth leakage current).
Since only the active and neutral conductors pass through the current transformer, the currents in these two conductors are no longer balanced and do not cancel.
This out-of-balance earth leakage current induces a voltage in the secondary of the current transformer, which is used to operate a relay and trip a circuit breaker.
If, for any reason, an earth leakage current flows through the operator, the imbalance between the currents in the active and neutral leads causes a current
to flow in the circuit of the secondary of the current transformer, which operates a relay and a circuit breaker, thus switching off the mains.
Notice that the mains system is MEN (Multiple Earth Neutral) as stated previously.
This protective system does not prevent current passing through the operator, but design considerations can keep this current low in value and flowing
only for a limited time, i.e. until the circuit breaker operates.
Portable devices of this kind operate on an earth current of 20 milliamperes and tripping times as low as 30 milliseconds.
The result of this combination of current and time is that the operator will be aware of the shock, but will experience no dangerous effects.
All these devices have re-set buttons that must be operated after the circuit breaker has been tripped.
Test buttons are also provided to enable the operator to ascertain whether the device is working according to the design specifications.
Most high schools have a device of this kind protecting the electric circuits in the laboratories and demonstration rooms.

4.2.9 Precautions to take when using core balance earth leakage devices
If the core balance earth leakage device trips during the operation of some equipment, a qualified electrician should be called to examine the equipment before it is used again.
Operate the test button once a week to ensure that the device is operating satisfactorily.

4.2.10 Management of electric shock victims
The rescuer must:
1. Turn off the electricity supply if possible.
OR
1a. Disconnect the victim from the electricity supply by the use of a dry non-conducting material e.g. dry clothing, a wooden stick.
2. Avoid any direct contact with the skin of the patient or any conducting material touching until disconnected.
3. Commence resuscitation.
Use cardiopulmonary resuscitation if the patient's heart has stopped beating.
4. Seek medical help.
4.2.11 Australian voltage
In 1983, Standards Australia adopted a 20 year plan to convert Australia from the nominal 240 volts to 230 volts, to align with European Standards - IEC38.
The aim was to align Australian manufactured products with the main trading partners.

3.6.2 Electrical safety rules
1. The apparatus in use has an up to date electrical safety tag (tag n test), label attached to the power lead.
2. The apparatus is connected to a Residual Current Device (Safety Switch).
Earth leakage detectors detects quite small currents to earth and turn of the supply very quickly to prevent electrocution.
3. The apparatus is only operated by the lecturer or trained personnel.
Never interfere with the mains.
Leave it to qualified persons.
4. Always carry-out a visual inspection of the apparatus before performing the demonstration.
5. Be aware of any tripping hazards due to leads on the floor.
6. Do not use electrical equipment if something has been spilled on or near the equipment.
7. Do not attempt to service any electrical apparatus unless you are qualified.
8. One is hand safer than two, because using two hands allows a current path across the chest.
The back of the hand is safer than the front of the hand, because the muscles that contract the hand are stronger than the muscles that flatten it.
9. Dry, rubber soled shoes can insulate you from the floor.
10. Even small shocks can be dangerous to a person on a metal ladder.
11. Power saws and electric mowers may cut their own cable and electrocute the user.
12. Dry skin is not a very good conductor, but people with electrodes attached to them, or metal catheters in their veins, or salty gels or bathing solution: have a low resistance pathway to their tissue and so are vulnerable.
Even static electric charges might be dangerous to them.
13. The master switches should be off before changing fuses.
14. Water is a conductor of electricity, so wet floors and baths are dangerous, because they provide a low resistance pathway from body tissues to the ground.
15. If there is an accident act quickly.
First ensure you will not be put in danger of electrical shock by attempting to help the victim.
Switch off the electrical supply before removing the casualty.
If breathing has stopped, begin artificial respiration at once, if possible by the FIRST AID officer.

Acknowledgement
The contents of this item have been adapted from "Aspects of Science Management: A Reference Manual for Schools", Department of Education, Queensland.
This manual has been adapted from many sources, including the previous Primary Science Safety Manual and Queensland Safety Handbook for
Schools, Science, handbooks of other state education Departments, and material from government agencies.
These sources are gratefully acknowledged.
All efforts were made to check that the information was accurate and current at the time of publication.
New legislation and regulations may be enacted from time to time.
New information regarding equipment and chemicals may become available.
Emergency procedures may be revised.
It remains the principal's responsibility to check for the latest information regarding legislation, regulations, policy and procedures that might affect a science activity.
These guidelines were prepared by the Studies Directorate.
Representatives from many sectors of the Education Department, tertiary institutions and professional associations have contributed to the development of this document.